Comment: zvyseno napeti

Golem shot: 7849

2012-03-29 - 210353



Basic parameters:
  • Chamber pressure pchamber : 3.40->10.51 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 500 V, triggered 8,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 350 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 29919 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.381 over 5.736 to 14.117 [ms]
  • Mean toroidal magnetic field Bt: 0.238 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: V
  • Break down voltage: 6.7 V
  • Plasma total charge: 6.0 C
  • Ohmic heating power: 5.5 kW
  • Q edge: 21.5
  • Central electron temperature: 28.8 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

MirnovCoils_JK

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and