Comment: Glow Discharge 14min He

Golem shot: 8035

2012-04-05 - 164407



Basic parameters:
  • Chamber pressure pchamber : 3.80->19.89 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5357 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.801 over 6.163 to 14.964 [ms]
  • Mean toroidal magnetic field Bt: 0.214 T
  • Mean plasma current: 0.7 kA
  • Mean Uloop: V
  • Break down voltage: 11.3 V
  • Plasma total charge: 4.1 C
  • Ohmic heating power: 7.6 kW
  • Q edge: 27.6
  • Central electron temperature: 14.5 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and