Comment: Final U_CD 400V

Golem shot: 8039

2012-04-05 - 173859



Basic parameters:
  • Chamber pressure pchamber : 3.59->21.80 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8648 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.567 over 4.692 to 15.259 [ms]
  • Mean toroidal magnetic field Bt: 0.236 T
  • Mean plasma current: 0.5 kA
  • Mean Uloop: V
  • Break down voltage: 10.0 V
  • Plasma total charge: 2.2 C
  • Ohmic heating power: 4.3 kW
  • Q edge: 42.6
  • Central electron temperature: 13.5 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and