Comment: CD from 400 to 350

Golem shot: 8071

2012-04-05 - 215816



Basic parameters:
  • Chamber pressure pchamber : 3.51->12.40 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 350 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5833 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 12.205 over 8.15 to 20.355 [ms]
  • Mean toroidal magnetic field Bt: 0.317 T
  • Mean plasma current: 0.5 kA
  • Mean Uloop: V
  • Break down voltage: 8.8 V
  • Plasma total charge: 3.9 C
  • Ohmic heating power: 3.5 kW
  • Q edge: 57.3
  • Central electron temperature: 15.5 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and