Comment: CD from 600 to 450

Golem shot: 8072

2012-04-05 - 220241



Basic parameters:
  • Chamber pressure pchamber : 3.53->10.16 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6099 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.87 over 8.869 to 18.739 [ms]
  • Mean toroidal magnetic field Bt: 0.296 T
  • Mean plasma current: 0.8 kA
  • Mean Uloop: V
  • Break down voltage: 10.8 V
  • Plasma total charge: 6.9 C
  • Ohmic heating power: 7.1 kW
  • Q edge: 33.4
  • Central electron temperature: 18.0 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and