Comment: CD from 600 to 450

Golem shot: 8075

2012-04-05 - 221702



Basic parameters:
  • Chamber pressure pchamber : 3.55->20.12 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6975 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.626 over 8.144 to 18.77 [ms]
  • Mean toroidal magnetic field Bt: 0.352 T
  • Mean plasma current: 0.5 kA
  • Mean Uloop: V
  • Break down voltage: 10.8 V
  • Plasma total charge: 4.3 C
  • Ohmic heating power: 4.7 kW
  • Q edge: 63.6
  • Central electron temperature: 12.8 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and