Comment: Increase ..

Golem shot: 8086

2012-04-05 - 234539



Basic parameters:
  • Chamber pressure pchamber : 3.58->10.08 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 1500 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4623 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.852 over 1.222 to 9.074 [ms]
  • Mean toroidal magnetic field Bt: 0.103 T
  • Mean plasma current: -0.7 kA
  • Mean Uloop: V
  • Break down voltage: -29.9 V
  • Plasma total charge: -0.8 C
  • Ohmic heating power: 4.7 kW
  • Q edge: 13.3
  • Central electron temperature: 19.9 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and