Comment: shifted to the 10th ms

Golem shot: 8107

2012-04-06 - 014634



Basic parameters:
  • Chamber pressure pchamber : 3.21->10.16 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 1000 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 00 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11901 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.836 over 4.809 to 15.645 [ms]
  • Mean toroidal magnetic field Bt: 0.286 T
  • Mean plasma current: 0.6 kA
  • Mean Uloop: V
  • Break down voltage: 20.5 V
  • Plasma total charge: 2.9 C
  • Ohmic heating power: 3.7 kW
  • Q edge: 43.0
  • Central electron temperature: 18.9 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Analysis:

SafetyFactor_JK

Thanks to the specific help and