Comment: repeat

Golem shot: 8111

2012-04-06 - 020833



Basic parameters:
  • Chamber pressure pchamber : 3.53->10.16 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 1200 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 00 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 13223 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.145 over 3.929 to 12.074 [ms]
  • Mean toroidal magnetic field Bt: 0.205 T
  • Mean plasma current: 0.9 kA
  • Mean Uloop: V
  • Break down voltage: 25.4 V
  • Plasma total charge: 3.6 C
  • Ohmic heating power: 5.9 kW
  • Q edge: 20.6
  • Central electron temperature: 23.8 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Analysis:

SafetyFactor_JK

Thanks to the specific help and