Comment: system check

Golem shot: 8320

2012-04-12 - 215856



Basic parameters:
  • Chamber pressure pchamber : 3.31->3.32 mPa (vacuum shot)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 10,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1457 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.03 over 24.08 to 31.11 [ms]
  • Mean toroidal magnetic field Bt: -0.686 T
  • Mean plasma current: -20.1 kA
  • Mean Uloop: V
  • Break down voltage: -3.0 V
  • Plasma total charge: -484.0 C
  • Ohmic heating power: 299.5 kW
  • Q edge: 3.1
  • Central electron temperature: 109.6 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and