Comment: system check

Golem shot: 8321

2012-04-12 - 220107



Basic parameters:
  • Chamber pressure pchamber : 3.34->3.31 mPa (vacuum shot)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 10,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1586 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 13.48 over 25.71 to 39.19 [ms]
  • Mean toroidal magnetic field Bt: 0.089 T
  • Mean plasma current: 34.8 kA
  • Mean Uloop: V
  • Break down voltage: 17.5 V
  • Plasma total charge: 894.4 C
  • Ohmic heating power: 382.8 kW
  • Q edge: 0.2
  • Central electron temperature: 193.5 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and