Comment: cyklus, plazma, Ubd =

Golem shot: 8332

2012-04-12 - 223456



Basic parameters:
  • Chamber pressure pchamber : 3.53->10.00 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 300 V, triggered 10,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3667 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.05 over 8.4 to 18.45 [ms]
  • Mean toroidal magnetic field Bt: 0.281 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: V
  • Break down voltage: 9.5 V
  • Plasma total charge: 9.2 C
  • Ohmic heating power: 9.0 kW
  • Q edge: 23.1
  • Central electron temperature: 23.5 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and