Comment: s vetr polem

Golem shot: 8348

2012-04-12 - 232316



Basic parameters:
  • Chamber pressure pchamber : 3.41->9.78 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 300 V, triggered 6,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6565 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.08 over 6.81 to 16.89 [ms]
  • Mean toroidal magnetic field Bt: 0.266 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 9.6 V
  • Plasma total charge: 9.7 C
  • Ohmic heating power: 11.8 kW
  • Q edge: 17.2
  • Central electron temperature: 27.2 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK