Comment: posun dal

Golem shot: 8351

2012-04-12 - 233210



Basic parameters:
  • Chamber pressure pchamber : 3.47->9.96 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 300 V, triggered 9,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7101 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.07 over 8.45 to 18.52 [ms]
  • Mean toroidal magnetic field Bt: 0.283 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: V
  • Break down voltage: 9.6 V
  • Plasma total charge: 10.0 C
  • Ohmic heating power: 9.8 kW
  • Q edge: 21.3
  • Central electron temperature: 24.9 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and