Comment: System check ..

Golem shot: 8357

2012-04-18 - 143510



Basic parameters:
  • Chamber pressure pchamber : 3.72->3.70 mPa (vacuum shot)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 10,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8372 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.09 over 32.12 to 39.21 [ms]
  • Mean toroidal magnetic field Bt: 1.994 T
  • Mean plasma current: 130.0 kA
  • Mean Uloop: V
  • Break down voltage: 4.9 V
  • Plasma total charge: 4176.8 C
  • Ohmic heating power: 819.0 kW
  • Q edge: 1.4
  • Central electron temperature: 675.6 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and