Comment: System check ..

Golem shot: 8359

2012-04-18 - 143944



Basic parameters:
  • Chamber pressure pchamber : 3.70->3.72 mPa (vacuum shot)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 10,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8645 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.31 over 31.88 to 39.19 [ms]
  • Mean toroidal magnetic field Bt: 0.166 T
  • Mean plasma current: 6.9 kA
  • Mean Uloop: V
  • Break down voltage: 4.6 V
  • Plasma total charge: 218.5 C
  • Ohmic heating power: 22.1 kW
  • Q edge: 2.2
  • Central electron temperature: 149.9 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

MirnovCoils_JK

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and