Comment: Chicago, US

Golem shot: 8393

2012-04-18 - 170426



Basic parameters:
  • Chamber pressure pchamber : 3.77->20.04 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8115 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.55 over 6.66 to 15.21 [ms]
  • Mean toroidal magnetic field Bt: 0.210 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: V
  • Break down voltage: 11.1 V
  • Plasma total charge: 6.6 C
  • Ohmic heating power: 10.8 kW
  • Q edge: 19.0
  • Central electron temperature: 18.4 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and