Comment: Chicago, US

Golem shot: 8394

2012-04-18 - 170652



Basic parameters:
  • Chamber pressure pchamber : 3.79->20.12 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8244 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.47 over 6.99 to 17.46 [ms]
  • Mean toroidal magnetic field Bt: 0.133 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: 10.9 V
  • Plasma total charge: 10.2 C
  • Ohmic heating power: 15.3 kW
  • Q edge: 8.0
  • Central electron temperature: 25.0 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and