Comment: Gomtraic MHD pH2=10

Golem shot: 8411

2012-04-19 - 170752



Basic parameters:
  • Chamber pressure pchamber : 3.38->9.55 mPa (request: 13 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 200 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 5,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 556 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 11.9 over 0.949999999999999 to 12.85 [ms]
  • Mean toroidal magnetic field Bt: 0.038 T
  • Mean plasma current: 0.6 kA
  • Mean Uloop: V
  • Break down voltage: 12.8 V
  • Plasma total charge: 0.6 C
  • Ohmic heating power: 7.0 kW
  • Q edge: 5.7
  • Central electron temperature: 12.4 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and