Comment: Gomtraic MHD pH2=10

Golem shot: 8432

2012-04-19 - 182333



Basic parameters:
  • Chamber pressure pchamber : 3.49->15.08 mPa (request: 12 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5108 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.01 over 5.78 to 13.79 [ms]
  • Mean toroidal magnetic field Bt: 0.061 T
  • Mean plasma current: 1.8 kA
  • Mean Uloop: V
  • Break down voltage: 12.8 V
  • Plasma total charge: 10.3 C
  • Ohmic heating power: 21.6 kW
  • Q edge: 3.1
  • Central electron temperature: 25.4 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and