Comment: Gomtraic MHD Tcd=1500

Golem shot: 8439

2012-04-19 - 183741



Basic parameters:
  • Chamber pressure pchamber : 3.51->20.04 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5955 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.65 over 5.52 to 14.17 [ms]
  • Mean toroidal magnetic field Bt: 0.062 T
  • Mean plasma current: 1.9 kA
  • Mean Uloop: V
  • Break down voltage: 13.2 V
  • Plasma total charge: 10.6 C
  • Ohmic heating power: 22.8 kW
  • Q edge: 2.9
  • Central electron temperature: 26.3 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and