Comment: Gomtraic MHD Tcd=4000

Golem shot: 8444

2012-04-19 - 184659



Basic parameters:
  • Chamber pressure pchamber : 3.88->19.96 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 4,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6514 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.96 over 6.28 to 17.24 [ms]
  • Mean toroidal magnetic field Bt: 0.083 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: V
  • Break down voltage: 12.3 V
  • Plasma total charge: 13.4 C
  • Ohmic heating power: 25.2 kW
  • Q edge: 3.6
  • Central electron temperature: 28.1 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and