Comment: Gomtraic MHD pH2=20

Golem shot: 8449

2012-04-19 - 185715



Basic parameters:
  • Chamber pressure pchamber : 3.69->23.63 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7137 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.18 over 7.97 to 17.15 [ms]
  • Mean toroidal magnetic field Bt: 0.125 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: V
  • Break down voltage: 11.4 V
  • Plasma total charge: 16.0 C
  • Ohmic heating power: 18.2 kW
  • Q edge: 5.6
  • Central electron temperature: 32.7 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and