Comment: No H test 2

Golem shot: 8500

2012-04-26 - 153933



Basic parameters:
  • Chamber pressure pchamber : 3.82->3.80 mPa (vacuum shot)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 350 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2899 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 5.61 over 2.55 to 8.16 [ms]
  • Mean toroidal magnetic field Bt: 0.045 T
  • Mean plasma current: -0.7 kA
  • Mean Uloop: V
  • Break down voltage: 4.3 V
  • Plasma total charge: -1.8 C
  • Ohmic heating power: 5.0 kW
  • Q edge: 5.8
  • Central electron temperature: 19.0 eV

DAS:

NIturbo

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and