Comment: Foceni 2

Golem shot: 8526

2012-04-27 - 112453



Basic parameters:
  • Chamber pressure pchamber : 3.32->9.96 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 350 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6321 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.69 over 5.29 to 13.98 [ms]
  • Mean toroidal magnetic field Bt: 0.131 T
  • Mean plasma current: 0.5 kA
  • Mean Uloop: V
  • Break down voltage: 8.6 V
  • Plasma total charge: 2.7 C
  • Ohmic heating power: 3.9 kW
  • Q edge: 23.7
  • Central electron temperature: 14.5 eV

DAS:

NIturbo

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and