Comment: Foceni 4

Golem shot: 8529

2012-04-27 - 114712



Basic parameters:
  • Chamber pressure pchamber : 3.34->9.96 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 350 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7660 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.11 over 5.84 to 13.95 [ms]
  • Mean toroidal magnetic field Bt: 0.125 T
  • Mean plasma current: 0.8 kA
  • Mean Uloop: V
  • Break down voltage: 8.3 V
  • Plasma total charge: 4.6 C
  • Ohmic heating power: 5.9 kW
  • Q edge: 14.1
  • Central electron temperature: 20.4 eV

DAS:

NIturbo

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and