Comment: dalsi test ..

Golem shot: 8651

2012-05-10 - 175407



Basic parameters:
  • Chamber pressure pchamber : 3.10->10.39 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1821 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.375 over 8.185 to 16.56 [ms]
  • Mean toroidal magnetic field Bt: 0.153 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 9.0 V
  • Plasma total charge: 11.3 C
  • Ohmic heating power: 10.9 kW
  • Q edge: 9.9
  • Central electron temperature: 28.6 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Laszlo

Acknowledgement: ,
Thanks to the specific help and