Comment: Investigating q_edge with different Bt

Golem shot: 8715

2012-05-10 - 213422



Basic parameters:
  • Chamber pressure pchamber : 3.04->10.04 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3743 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.28 over 9.915 to 18.195 [ms]
  • Mean toroidal magnetic field Bt: 0.158 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: 8.8 V
  • Plasma total charge: 14.4 C
  • Ohmic heating power: 11.4 kW
  • Q edge: 9.5
  • Central electron temperature: 30.4 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Laszlo

Acknowledgement: ,
Thanks to the specific help and