Comment: ShotNo:474

Golem shot: 8793

2012-05-24 - 182550



Basic parameters:
  • Chamber pressure pchamber : 3.16->13.76 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 300 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 550 V, triggered 4,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1534 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.925 over 1.23 to 12.155 [ms]
  • Mean toroidal magnetic field Bt: 0.048 T
  • Mean plasma current: 0.7 kA
  • Mean Uloop: V
  • Break down voltage: 11.6 V
  • Plasma total charge: 0.9 C
  • Ohmic heating power: 6.8 kW
  • Q edge: 6.2
  • Central electron temperature: 15.6 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and