Comment: ShotNo:482

Golem shot: 8801

2012-05-24 - 190353



Basic parameters:
  • Chamber pressure pchamber : 3.24->10.04 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 6,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3824 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 12.5 over 7.99 to 20.49 [ms]
  • Mean toroidal magnetic field Bt: 0.096 T
  • Mean plasma current: 2.6 kA
  • Mean Uloop: V
  • Break down voltage: 11.4 V
  • Plasma total charge: 20.6 C
  • Ohmic heating power: 28.6 kW
  • Q edge: 3.3
  • Central electron temperature: 34.3 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and