Comment: ShotNo:484

Golem shot: 8803

2012-05-24 - 190834



Basic parameters:
  • Chamber pressure pchamber : 3.25->9.96 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 10,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4107 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 16.48 over 6.915 to 23.395 [ms]
  • Mean toroidal magnetic field Bt: 0.104 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: V
  • Break down voltage: 10.9 V
  • Plasma total charge: 14.6 C
  • Ohmic heating power: 23.7 kW
  • Q edge: 4.5
  • Central electron temperature: 29.2 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and