Comment: ShotNo:496

Golem shot: 8815

2012-05-24 - 193832



Basic parameters:
  • Chamber pressure pchamber : 3.30->14.40 mPa (request: 16 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5903 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.825 over 1.59 to 10.415 [ms]
  • Mean toroidal magnetic field Bt: 0.048 T
  • Mean plasma current: 0.9 kA
  • Mean Uloop: V
  • Break down voltage: 12.5 V
  • Plasma total charge: 1.5 C
  • Ohmic heating power: 9.5 kW
  • Q edge: 4.8
  • Central electron temperature: 17.5 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and