Comment: Shot 483 with Bd

Golem shot: 8833

2012-05-24 - 204513



Basic parameters:
  • Chamber pressure pchamber : 3.24->9.93 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 9,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 8,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 9906 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 14.47 over 7.61 to 22.08 [ms]
  • Mean toroidal magnetic field Bt: 0.101 T
  • Mean plasma current: 2.4 kA
  • Mean Uloop: V
  • Break down voltage: 10.7 V
  • Plasma total charge: 18.4 C
  • Ohmic heating power: 26.4 kW
  • Q edge: 3.8
  • Central electron temperature: 32.5 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and