Comment: Shot 485 with Bd

Golem shot: 8835

2012-05-24 - 205013



Basic parameters:
  • Chamber pressure pchamber : 3.27->15.92 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 4,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 10221 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.175 over 10.645 to 20.82 [ms]
  • Mean toroidal magnetic field Bt: 0.174 T
  • Mean plasma current: 3.1 kA
  • Mean Uloop: V
  • Break down voltage: 11.6 V
  • Plasma total charge: 32.5 C
  • Ohmic heating power: 30.1 kW
  • Q edge: 5.1
  • Central electron temperature: 42.0 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and