Comment: Shot 486 with Bd

Golem shot: 8836

2012-05-24 - 205242



Basic parameters:
  • Chamber pressure pchamber : 3.30->19.96 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 6,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 6,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 10372 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 12.33 over 9.96 to 22.29 [ms]
  • Mean toroidal magnetic field Bt: 0.180 T
  • Mean plasma current: 3.0 kA
  • Mean Uloop: V
  • Break down voltage: 11.4 V
  • Plasma total charge: 29.5 C
  • Ohmic heating power: 29.4 kW
  • Q edge: 5.4
  • Central electron temperature: 40.8 eV

DAS:

NIturbo

Papouch_St

NIbasic.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and