Comment: NIbasic nahrazeno NIstandard

Golem shot: 8887

2012-05-30 - 121014



Basic parameters:
  • Chamber pressure pchamber : 1.82->1.83 mPa (vacuum shot)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11745 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 5.123 over 34.796 to 39.919 [ms]
  • Mean toroidal magnetic field Bt: 1.034 T
  • Mean plasma current: 9.7 kA
  • Mean Uloop: V
  • Break down voltage: -11.2 V
  • Plasma total charge: 338.0 C
  • Ohmic heating power: 255.1 kW
  • Q edge: 9.6
  • Central electron temperature: 46.2 eV

DAS:

NIturbo

TektronixDPO3014

Papouch_St

NIstandard.ONN
Diagnostics: (configuration)

FastCamera

Spectrometer

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and