Comment: Preionization really back in operation, repeat, position pozice=60

Golem shot: 8920

2012-05-31 - 191151



Basic parameters:
  • Chamber pressure pchamber : 1.21->10.04 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1100 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6631 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.819 over 10.963 to 19.782 [ms]
  • Mean toroidal magnetic field Bt: 0.262 T
  • Mean plasma current: 3.1 kA
  • Mean Uloop: V
  • Break down voltage: 11.7 V
  • Plasma total charge: 33.7 C
  • Ohmic heating power: 31.3 kW
  • Q edge: 7.6
  • Central electron temperature: 40.9 eV

DAS:

NIturbo

TektronixDPO3014

Papouch_St

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

RakeProbe

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and