Comment: OK, position 60to50 pozice=50

Golem shot: 8921

2012-05-31 - 191808



Basic parameters:
  • Chamber pressure pchamber : 1.19->10.28 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1100 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7009 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.758 over 10.006 to 18.764 [ms]
  • Mean toroidal magnetic field Bt: 0.257 T
  • Mean plasma current: 2.7 kA
  • Mean Uloop: V
  • Break down voltage: 11.5 V
  • Plasma total charge: 26.6 C
  • Ohmic heating power: 28.9 kW
  • Q edge: 8.6
  • Central electron temperature: 35.9 eV

DAS:

NIturbo

TektronixDPO3014

Papouch_St

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

RakeProbe

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and