Comment: OK, still pressure problem, repeat .. position=pozice=60

Golem shot: 8933

2012-05-31 - 202948



Basic parameters:
  • Chamber pressure pchamber : 1.07->4.90 mPa (request: 5 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11328 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.711 over 8.388 to 18.099 [ms]
  • Mean toroidal magnetic field Bt: 0.337 T
  • Mean plasma current: 0.8 kA
  • Mean Uloop: V
  • Break down voltage: 9.3 V
  • Plasma total charge: 7.0 C
  • Ohmic heating power: 6.5 kW
  • Q edge: 38.0
  • Central electron temperature: 19.2 eV

DAS:

NIturbo

TektronixDPO3014

Papouch_St

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

RakeProbe

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and