Comment: Rake on position=60

Golem shot: 9012

2012-06-07 - 173927



Basic parameters:
  • Chamber pressure pchamber : 1.94->9.89 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 350 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2874 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.219 over 6.742 to 14.961 [ms]
  • Mean toroidal magnetic field Bt: 0.165 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: V
  • Break down voltage: 8.4 V
  • Plasma total charge: 6.9 C
  • Ohmic heating power: 7.0 kW
  • Q edge: 14.9
  • Central electron temperature: 24.5 eV

DAS:

NIturbo

TektronixDPO3014

Papouch_St

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

RakeProbe

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and