Comment: Martinez 1, rake probe position=60

Golem shot: 9014

2012-06-07 - 175047



Basic parameters:
  • Chamber pressure pchamber : 2.00->19.96 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 900 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3561 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.13 over 8.172 to 16.302 [ms]
  • Mean toroidal magnetic field Bt: 0.194 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: V
  • Break down voltage: 12.3 V
  • Plasma total charge: 16.9 C
  • Ohmic heating power: 24.4 kW
  • Q edge: 8.3
  • Central electron temperature: 28.7 eV

DAS:

NIturbo

TektronixDPO3014

Papouch_St

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

RakeProbe

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and