Comment: Martinez 9, rake probe position=60

Golem shot: 9031

2012-06-07 - 193335



Basic parameters:
  • Chamber pressure pchamber : 2.00->20.04 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 900 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 9726 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.592 over 6.637 to 15.229 [ms]
  • Mean toroidal magnetic field Bt: 0.191 T
  • Mean plasma current: 0.8 kA
  • Mean Uloop: V
  • Break down voltage: 13.9 V
  • Plasma total charge: 5.5 C
  • Ohmic heating power: 10.5 kW
  • Q edge: 21.6
  • Central electron temperature: 13.9 eV

DAS:

NIturbo

TektronixDPO3014

Papouch_St

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

RakeProbe

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and