Comment: Pravesh 1, rake probe position=60

Golem shot: 9039

2012-06-07 - 201245



Basic parameters:
  • Chamber pressure pchamber : 1.95->12.50 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 12083 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.311 over 7.598 to 16.909 [ms]
  • Mean toroidal magnetic field Bt: 0.233 T
  • Mean plasma current: 0.8 kA
  • Mean Uloop: V
  • Break down voltage: 10.8 V
  • Plasma total charge: 6.4 C
  • Ohmic heating power: 8.6 kW
  • Q edge: 26.3
  • Central electron temperature: 15.8 eV

DAS:

NIturbo

TektronixDPO3014

Papouch_St

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

RakeProbe

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and