Comment: HXR test

Golem shot: 9057

2012-06-08 - 113610



Basic parameters:
  • Chamber pressure pchamber : 2.96->11.10 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1633 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.557 over 8.467 to 17.024 [ms]
  • Mean toroidal magnetic field Bt: 0.181 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: V
  • Break down voltage: 10.0 V
  • Plasma total charge: 17.4 C
  • Ohmic heating power: 24.8 kW
  • Q edge: 7.8
  • Central electron temperature: 28.4 eV

DAS:

NIturbo

TektronixDPO3014

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

MirnovCoils_JK

FastCamera

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and