Comment: Force runaway generation

Golem shot: 9067

2012-06-08 - 130210



Basic parameters:
  • Chamber pressure pchamber : 2.84->9.26 mPa (request: 7 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 700 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2323 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.28 over 9.307 to 17.587 [ms]
  • Mean toroidal magnetic field Bt: 0.182 T
  • Mean plasma current: 2.8 kA
  • Mean Uloop: V
  • Break down voltage: 10.5 V
  • Plasma total charge: 25.7 C
  • Ohmic heating power: 36.4 kW
  • Q edge: 5.9
  • Central electron temperature: 32.3 eV

DAS:

NIturbo

TektronixDPO3014

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

MirnovCoils_JK

FastCamera

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and