Comment: Force runaway generation

Golem shot: 9068

2012-06-08 - 130605



Basic parameters:
  • Chamber pressure pchamber : 2.85->7.08 mPa (request: 4 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 700 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2556 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.251 over 9.571 to 17.822 [ms]
  • Mean toroidal magnetic field Bt: 0.183 T
  • Mean plasma current: 2.9 kA
  • Mean Uloop: V
  • Break down voltage: 10.5 V
  • Plasma total charge: 27.5 C
  • Ohmic heating power: 37.1 kW
  • Q edge: 5.7
  • Central electron temperature: 33.4 eV

DAS:

NIturbo

TektronixDPO3014

NIstandard.ONN
Diagnostics: (configuration)

MHD_TM

MirnovCoils_JK

FastCamera

HXR_LK

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and