Comment: Just runaway No:514

Golem shot: 9417

2012-06-29 - 151431



Basic parameters:
  • Chamber pressure pchamber : 0.64->9.78 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 300 V, triggered 9,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 4,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7631 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.307 over 7.277 to 17.584 [ms]
  • Mean toroidal magnetic field Bt: 0.198 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: V
  • Break down voltage: 9.6 V
  • Plasma total charge: 11.7 C
  • Ohmic heating power: 20.6 kW
  • Q edge: 11.2
  • Central electron temperature: 22.3 eV

DAS:

NIturbo

NIbasic

NIstandard.ONN
Diagnostics: (configuration)

Flukes

HXR_OG

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and