Comment: Just runaway No:511 once more again

Golem shot: 9422

2012-06-29 - 153709



Basic parameters:
  • Chamber pressure pchamber : 0.66->10.04 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 300 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 4,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8978 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.158 over 6.909 to 17.067 [ms]
  • Mean toroidal magnetic field Bt: 0.145 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: V
  • Break down voltage: 10.6 V
  • Plasma total charge: 10.8 C
  • Ohmic heating power: 20.5 kW
  • Q edge: 8.2
  • Central electron temperature: 22.4 eV

DAS:

NIturbo

NIbasic

NIstandard.ONN
Diagnostics: (configuration)

Flukes

HXR_OG

Analysis:

SafetyFactor_JK

Acknowledgement: ,
Thanks to the specific help and