14:58:32 #37777 Discharge/PrepareDischargeEnv@SHM: Command Line Request: SOC@USA 14:58:32 #37777 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 14:58:33 #37777 /VacuumLog: Chamber: 1.07 mPa, 35.30 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 14:58:34 #37777 /GetReadyTheDischarge: Going with gas pressure 16 14:58:34 #37777 /GetReadyTheDischarge: Going with gas type H 14:58:34 #37777 /GetReadyTheDischarge: Discharge with Hydrogen request 14:58:34 #37777 /GetReadyTheDischarge: Discharge with 16 mPa request TheDischarge 14:58:34 #37777 /LogTheDeviceAction: The Trigger action on stage wi14:58:34 #37777 /GetReadyTheDischarge: Going with Bt_orientation CW 14:58:34 #37777 /GetReadyTheDischarge: Discharge with Bt CW request 14:58:34 #37777 /GetReadyTheDischarge: Going with CD_orientation CW 14:58:34 #37777 /GetReadyTheDischarge: Discharge with CD CW request 14:58:37 #37777 /VacuumLog: Chamber: 1.45 mPa, 35.30 C, ForVacuum: 0.975 Pa, Gas: H2, GasValve: 23.63 V 14:58:40 #37777 /VacuumLog: Chamber: 18.70 mPa, 35.30 C, ForVacuum: 2.1 Pa, Gas: H2, GasValve: 25.49 V 14:58:41 #37777 /GetReadyTheDischarge: Bt capacitor charging started 14:58:45 #37777 /VacuumLog: Chamber: 13.60 mPa, 35.30 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 22.73 V 14:58:46 #37777 /GetReadyTheDischarge: Cd capacitor charging started 14:58:46 #37777 /ChargingResistorsAllOFF: Diving into .. 14:58:46 #37777 /GetReadyTheDischarge: U_Bt: 450, Hrana: 98 14:58:46 #37777 /GetReadyTheDischarge: U_Et: 600, Hrana: 98 14:58:46 #37777 /GetReadyTheDischarge: Charging ... HV=-11 V 14:58:47 #37777 /GetReadyTheDischarge: Charging ... HV=4 V 14:58:48 #37777 /GetReadyTheDischarge: Charging ... HV=21 V 14:58:49 #37777 /GetReadyTheDischarge: Charging ... HV=99 V 14:58:49 #37777 /GetReadyTheDischarge: Charging ... HV=99 V 14:58:50 #37777 /GetReadyTheDischarge: Charging ... HV=99 V 14:58:50 #37777 /GetReadyTheDischarge: Charging ... HV=144 V 14:58:51 #37777 /GetReadyTheDischarge: Charging ... HV=144 V 14:58:51 #37777 /GetReadyTheDischarge: Charging ... HV=189 V 14:58:51 #37777 /GetReadyTheDischarge: Charging ... HV=189 V 14:58:52 #37777 /GetReadyTheDischarge: Charging ... HV=189 V 14:58:52 #37777 /GetReadyTheDischarge: Charging ... HV=235 V 14:58:53 #37777 /GetReadyTheDischarge: Charging ... HV=235 V 14:58:53 #37777 /GetReadyTheDischarge: Charging ... HV=279 V 14:58:54 #37777 /GetReadyTheDischarge: Charging ... HV=279 V 14:58:55 #37777 /GetReadyTheDischarge: Charging ... HV=322 V 14:58:55 #37777 /GetReadyTheDischarge: Charging ... HV=322 V 14:58:56 #37777 /GetReadyTheDischarge: Charging ... HV=362 V 14:58:56 #37777 /GetReadyTheDischarge: Charging ... HV=362 V 14:58:57 #37777 /VacuumLog: Chamber: 17.20 mPa, 35.30 C, ForVacuum: 4.25 Pa, Gas: H2, GasValve: 23.22 V 14:58:57 #37777 /GetReadyTheDischarge: Charging ... HV=400 V 14:58:57 #37777 /GetReadyTheDischarge: Charging ... HV=400 V 14:58:58 #37777 /GetReadyTheDischarge: Charging ... HV=438 V 14:58:58 #37777 /GetReadyTheDischarge: Charging ... HV=438 V 14:58:59 #37777 /GetReadyTheDischarge: Charging ... HV=477 V 14:58:59 #37777 /GetReadyTheDischarge: Bt capacitor charging finished @ 477 V 14:59:00 #37777 /GetReadyTheDischarge: Charging ... HV=21 V 14:59:00 #37777 /GetReadyTheDischarge: Charging ... HV=522 V 14:59:00 #37777 /GetReadyTheDischarge: Charging ... HV=522 V 14:59:01 #37777 /GetReadyTheDischarge: Charging ... HV=774 V 14:59:01 #37777 /ChargingResistorsAllON: Diving into .. 14:59:01 #37777 /GetReadyTheDischarge: Cd capacitor charging finished @ 774 V 14:59:02 #37777 /ChargingResistorsAllON: Diving into .. 14:59:02 #37777 /GetReadyTheDischarge: Ascending from .. 14:59:02 #37777 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 14:59:04 #37777 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 14:59:04 #37777 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 14:59:04 #37777 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 14:59:04 #37777 /VacuumLog: Chamber: 16.90 mPa, 35.30 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 23.22 V 14:59:08 #37777 /VacuumLog: Chamber: 16.80 mPa, 35.30 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 23.22 V 14:59:12 #37777 /VacuumLog: Chamber: 16.70 mPa, 35.30 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 23.22 V 14:59:15 #37777 /Trigger: Going through .. 14:59:15 #37777 Discharge/HWTrigger: Going through .. 14:59:15 #37777 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 14:59:15 #37777 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 6000 14:59:15 #37777 Discharge/HWTrigger: Going with trigger Tch5 - Tist -1000 14:59:15 #37777 /VacuumLog: Chamber: 16.70 mPa, 35.30 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 23.22 V 14:59:19 #37777 /VacuumLog: Chamber: 19.20 mPa, 35.30 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 23.22 V 14:59:19 #37777 /ChargingResistorsAllON: Diving into .. 14:59:22 #37777 /SecurePostDischargeState: Going through .. 14:59:22 #37777 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 14:59:22 #37777 /VacuumLog: Chamber: 2.01 mPa, 35.30 C, ForVacuum: 3.05 Pa, Gas: NULL, GasValve: 0.00 V 14:59:26 #37777 /VacuumLog: Chamber: 1.50 mPa, 35.40 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 14:59:27 #37777 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 14:59:30 #37777 /VacuumLog: Chamber: 1.39 mPa, 35.40 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 14:59:30 #37777 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 14:59:31 #37777 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 14:59:33 #37777 /VacuumLog: Chamber: 1.32 mPa, 35.40 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 14:59:37 #37777 /VacuumLog: Chamber: 1.27 mPa, 35.40 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 14:59:39 #37777 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 14:59:41 #37777 /VacuumLog: Chamber: 1.24 mPa, 35.40 C, ForVacuum: 0.955 Pa, Gas: NULL, GasValve: 0.00 V 14:59:44 #37777 /VacuumLog: Chamber: 1.21 mPa, 35.40 C, ForVacuum: 0.96 Pa, Gas: NULL, GasValve: 0.00 V 14:59:48 #37777 /VacuumLog: Chamber: 1.19 mPa, 35.40 C, ForVacuum: 0.96 Pa, Gas: NULL, GasValve: 0.00 V 14:59:50 #37777 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 14:59:52 #37777 /VacuumLog: Chamber: 1.17 mPa, 35.40 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 14:59:56 #37777 /VacuumLog: Chamber: 1.16 mPa, 35.40 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 14:59:57 #37777 /DischargeFunction: General Calling FinalDischargeOperations 14:59:59 #37777 /VacuumLog: Chamber: 1.14 mPa, 35.40 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V