15:15:44 #38492 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Strip detector commissioning 15:15:45 #38492 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 15:15:45 #38492 /VacuumLog: Chamber: 1.05 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:15:46 #38492 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 15:15:47 #38492 /GetReadyTheDischarge: Going with gas pressure 12 15:15:47 #38492 /GetReadyTheDischarge: Going with gas type H 15:15:47 #38492 /GetReadyTheDischarge: Discharge with Hydrogen request 15:15:47 #38492 /GetReadyTheDischarge: Discharge with 12 mPa request 15:15:47 #38492 /GetReadyTheDischarge: Discharge with Bt CW request 15:15:47 #38492 /GetReadyTheDischarge: Going with CD_orientation CW 15:15:47 #38492 /GetReadyTheDischarge: Discharge with CD CW request 15:15:48 #38492 /VacuumLog: Chamber: 1.05 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 21.46 V 15:15:52 #38492 /VacuumLog: Chamber: 16.70 mPa, 30.40 C, ForVacuum: 2.25 Pa, Gas: H2, GasValve: 22.59 V 15:15:54 #38492 /GetReadyTheDischarge: Bt capacitor charging started 15:15:56 #38492 /VacuumLog: Chamber: 12.40 mPa, 30.40 C, ForVacuum: 4.35 Pa, Gas: H2, GasValve: 20.57 V 15:15:58 #38492 /GetReadyTheDischarge: Cd capacitor charging started 15:15:58 #38492 /ChargingResistorsAllOFF: Diving into .. 15:15:59 #38492 /GetReadyTheDischarge: U_Bt: 1000, Hrana: 98 15:15:59 #38492 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 15:15:59 #38492 /GetReadyTheDischarge: Charging ... HV=-11 V 15:15:59 #38492 /GetReadyTheDischarge: Charging ... HV=21 V a, Gas: H2, GasValve: 20.95 V 15:16:00 #38492 /GetReadyTheDischarge: Charging ... HV=-11 V 15:16:00 #38492 /GetReadyTheDischarge: Charging ... HV=13 V 15:16:01 #38492 /GetReadyTheDischarge: Charging ... HV=13 V 15:16:01 #38492 /GetReadyTheDischarge: Charging ... HV=61 V 15:16:01 #38492 /GetReadyTheDischarge: Charging ... HV=61 V 15:16:02 #38492 /GetReadyTheDischarge: Charging ... HV=61 V 15:16:02 #38492 /GetReadyTheDischarge: Charging ... HV=108 V 15:16:03 #38492 /GetReadyTheDischarge: Charging ... HV=21 V 15:16:03 #38492 /GetReadyTheDischarge: Charging ... HV=155 V , Gas: H2, GasValve: 20.89 V 15:16:04 #38492 /GetReadyTheDischarge: Charging ... HV=155 V 15:16:04 #38492 /GetReadyTheDischarge: Charging ... HV=201 V 15:16:05 #38492 /GetReadyTheDischarge: Charging ... HV=201 V 15:16:05 #38492 /GetReadyTheDischarge: Charging ... HV=201 V 15:16:05 #38492 /GetReadyTheDischarge: Charging ... HV=246 V 15:16:06 #38492 /GetReadyTheDischarge: Charging ... HV=246 V 15:16:06 #38492 /GetReadyTheDischarge: Charging ... HV=290 V 15:16:07 #38492 /GetReadyTheDischarge: Charging ... HV=290 V 15:16:07 #38492 /GetReadyTheDischarge: Charging ... HV=290 V 15:16:08 #38492 /GetReadyTheDischarge: Charging ... HV=334 V 15:16:08 #38492 /GetReadyTheDischarge: Charging ... HV=334 V 15:16:08 #38492 /GetReadyTheDischarge: Charging ... HV=374 V 15:16:09 #38492 /GetReadyTheDischarge: Charging ... HV=374 V 15:16:09 #38492 /GetReadyTheDischarge: Charging ... HV=374 V 15:16:10 #38492 /GetReadyTheDischarge: Charging ... HV=412 V 15:16:10 #38492 /VacuumLog: Chamber: 11.50 mPa, 30.40 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 20.89 V 15:16:10 #38492 /GetReadyTheDischarge: Charging ... HV=412 V 15:16:11 #38492 /GetReadyTheDischarge: Charging ... HV=452 V 15:16:11 #38492 /GetReadyTheDischarge: Cd capacitor charging finished @ 452 V 15:16:11 #38492 /GetReadyTheDischarge: Charging ... HV=452 V 15:16:12 #38492 /GetReadyTheDischarge: Charging ... HV=490 V 15:16:12 #38492 /GetReadyTheDischarge: Charging ... HV=490 V 15:16:12 #38492 /GetReadyTheDischarge: Charging ... HV=490 V 15:16:13 #38492 /GetReadyTheDischarge: Charging ... HV=530 V 15:16:13 #38492 /GetReadyTheDischarge: Charging ... HV=530 V 15:16:14 #38492 /GetReadyTheDischarge: Charging ... HV=569 V 15:16:14 #38492 /VacuumLog: Chamber: 11.40 mPa, 30.40 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 20.89 V 15:16:14 #38492 /GetReadyTheDischarge: Charging ... HV=569 V 15:16:15 #38492 /GetReadyTheDischarge: Charging ... HV=569 V 15:16:15 #38492 /GetReadyTheDischarge: Charging ... HV=606 V 15:16:15 #38492 /GetReadyTheDischarge: Charging ... HV=606 V 15:16:16 #38492 /GetReadyTheDischarge: Charging ... HV=606 V 15:16:16 #38492 /GetReadyTheDischarge: Charging ... HV=640 V 15:16:17 #38492 /GetReadyTheDischarge: Charging ... HV=640 V 15:16:17 #38492 /GetReadyTheDischarge: Charging ... HV=678 V 15:16:18 #38492 /GetReadyTheDischarge: Charging ... HV=678 V Gas: H2, GasValve: 20.89 V 15:16:18 #38492 /GetReadyTheDischarge: Charging ... HV=678 V 15:16:18 #38492 /GetReadyTheDischarge: Charging ... HV=713 V 15:16:19 #38492 /GetReadyTheDischarge: Charging ... HV=713 V 15:16:19 #38492 /GetReadyTheDischarge: Charging ... HV=21 V 15:16:20 #38492 /GetReadyTheDischarge: Charging ... HV=745 V 15:16:20 #38492 /GetReadyTheDischarge: Charging ... HV=745 V 15:16:21 #38492 /GetReadyTheDischarge: Charging ... HV=776 V 15:16:21 #38492 /GetReadyTheDischarge: Charging ... HV=776 V 15:16:21 #38492 /GetReadyTheDischarge: Charging ... HV=807 V Gas: H2, GasValve: 20.89 V 15:16:22 #38492 /GetReadyTheDischarge: Charging ... HV=807 V 15:16:22 #38492 /GetReadyTheDischarge: Charging ... HV=807 V 15:16:23 #38492 /GetReadyTheDischarge: Charging ... HV=839 V 15:16:23 #38492 /GetReadyTheDischarge: Charging ... HV=839 V 15:16:23 #38492 /GetReadyTheDischarge: Charging ... HV=867 V 15:16:24 #38492 /GetReadyTheDischarge: Charging ... HV=867 V 15:16:24 #38492 /GetReadyTheDischarge: Charging ... HV=867 V 15:16:25 #38492 /GetReadyTheDischarge: Charging ... HV=898 V 15:16:25 #38492 /GetReadyTheDischarge: Charging ... HV=898 V 15:16:26 #38492 /GetReadyTheDischarge: Charging ... HV=925 V 15:16:26 #38492 /GetReadyTheDischarge: Charging ... HV=925 V 15:16:26 #38492 /GetReadyTheDischarge: Charging ... HV=925 V 15:16:27 #38492 /GetReadyTheDischarge: Charging ... HV=954 V 15:16:27 #38492 /GetReadyTheDischarge: Charging ... HV=954 V 15:16:28 #38492 /GetReadyTheDischarge: Charging ... HV=980 V 15:16:28 #38492 /GetReadyTheDischarge: Charging ... HV=980 V 15:16:29 #38492 /GetReadyTheDischarge: Charging ... HV=980 V 15:16:29 #38492 /GetReadyTheDischarge: Charging ... HV=1005 V 15:16:29 #38492 /ChargingResistorsAllON: Diving into .. 15:16:30 #38492 /GetReadyTheDischarge: Bt capacitor charging finished @ 1005 V 15:16:30 #38492 /ChargingResistorsAllON: Diving into .. 15:16:30 #38492 /GetReadyTheDischarge: Ascending from .. 15:16:30 #38492 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 15:16:32 #38492 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:16:32 #38492 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:16:32 #38492 /VacuumLog: Chamber: 11.00 mPa, 30.40 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 20.89 V 15:16:36 #38492 /VacuumLog: Chamber: 11.00 mPa, 30.30 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 20.89 V 15:16:39 #38492 /VacuumLog: Chamber: 10.90 mPa, 30.30 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 20.89 V 15:16:41 #38492 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 15:16:43 #38492 /VacuumLog: Chamber: 10.90 mPa, 30.30 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 20.89 V 15:16:47 #38492 /VacuumLog: Chamber: 10.80 mPa, 30.30 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 20.89 V 15:16:50 #38492 /VacuumLog: Chamber: 10.80 mPa, 30.30 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 20.89 V 15:16:51 #38492 /Trigger: Going through .. 15:16:51 #38492 Discharge/HWTrigger: Going through .. 15:16:51 #38492 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 15:16:51 #38492 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 15:16:51 #38492 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 15:16:54 #38492 /VacuumLog: Chamber: 10.70 mPa, 30.30 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 20.89 V 15:16:56 #38492 /ChargingResistorsAllON: Diving into .. 15:16:57 #38492 /VacuumLog: Chamber: 6.24 mPa, 30.30 C, ForVacuum: 3.5 Pa, Gas: H2, GasValve: 0.00 V 15:16:58 #38492 /SecurePostDischargeState: Going through .. 15:16:58 #38492 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 15:17:01 #38492 /VacuumLog: Chamber: 1.25 mPa, 30.40 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 15:17:03 #38492 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 15:17:05 #38492 /VacuumLog: Chamber: 1.18 mPa, 30.40 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 15:17:08 #38492 /VacuumLog: Chamber: 1.14 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:12 #38492 /VacuumLog: Chamber: 1.11 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:16 #38492 /VacuumLog: Chamber: 1.10 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:17 #38492 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 15:17:19 #38492 /VacuumLog: Chamber: 1.08 mPa, 30.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:23 #38492 /VacuumLog: Chamber: 1.07 mPa, 30.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:27 #38492 /VacuumLog: Chamber: 1.07 mPa, 30.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:30 #38492 /VacuumLog: Chamber: 1.06 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:34 #38492 /VacuumLog: Chamber: 1.05 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:38 #38492 /VacuumLog: Chamber: 1.05 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:41 #38492 /VacuumLog: Chamber: 1.05 mPa, 30.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:45 #38492 /VacuumLog: Chamber: 1.05 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:48 #38492 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 15:17:49 #38492 /VacuumLog: Chamber: 1.05 mPa, 30.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:52 #38492 /VacuumLog: Chamber: 1.05 mPa, 30.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:17:55 #38492 /DischargeFunction: General Calling FinalDischargeOperations